Air compressor legislation

The use of compressed air as a source of respiratory protection is covered by various standards, COSHH and Codes of Practice. Below is a summary of the main points to consider when making decision relating to selection of suitable equipment. For more information, contact Willpower Breathing Air Ltd in Birmingham today.

Air Compressor Legislation: Welcome

Home Improvement Services

Home Improvement Done Right

24arbest.jpg

Current compliance levels:

Carbon Monoxide >3 ppm
Carbon Dioxide >500 ppm
Oxygen 20-23%
Oil Mist .05 mg/m³
Odour/Taste Without significant odour or taste
Water Vapour 5ºC below lowest ambient or -11ºC
All other contaminants 10% EH40 Levels


BSEN 529
EN12021
EH40
COSHH
HSG53

The main points to consider when designing a compressed air system to provide breathable quality air are:

1) Air quality requirements. The air supplied to the user must conform to all the above standards, in particular it should meet the requirements of the table above.

2) Air quality testing. The air quality should be tested for foreseeable contaminants at least monthly or more often if necessary. The air quality test is NOT a control measure and only forms part of the process of providing breathable air.

3) Selection of suitable control measures. When a risk assessment, or the standards, identify possible risks it is necessary to install a control measure to protect from, or remove, each of those risks. The inclusion of the control measure coupled with the air quality test will help to ensure breathable quality air.

18arcbest_edited.jpg
P18srcut_edited.jpg

How Niltox purifiers provide the solution

Niltox purifiers remove carbon monoxide, carbon dioxide, oil & water vapour, oil and water, smells, tastes, dirt, dust, and doubt. Thus, the purifier provides the control measure. The built-in colour indicator shows that the control measure is operating and, hence removing the risk. This will enable users to avoid monthly air quality testing.

Niltox purifiers remove the contamination, the need for expensive tests, and the doubt!


Follow this link to an extract from BSEN 529 that shows the stages required in a compressed air breathing system. Niltox units provide the components from A2.8 to A2.11.

Air Compressor Legislation: Services

Keep up to date with the latest legislation and make sure you stay safe and compliant

For more information, contact Willpower Breathing Air in Birmingham on

0121 605 2600

Air Compressor Legislation: Text

Contact Us

Unit 6, Granby Business Park
Granby Avenue
Garretts Green
Birmingham
B33 0TJ

Thanks for submitting!

Air Compressor Legislation: Contact
bottom of page